SM-7
GAS FIRED BROILERS
DRIP TRAY AND HORIZONTAL
GREASE CONTAINER.
The drip tray is located below the drip deflector.
Grease dripping onto the drip deflector runs off the
back edge to the drip tray then flows forward into the
horizontal grease container.
1. Pull the drip tray straight out the front of the
broiler.
2. Lift the horizontal grease container up and away
from the broiler.
NOTE: When dumping the contents of the
horizontal grease container, be sure to follow
appropriate regulations for disposing of grease.
Figure 4. Drip Tray and Grease Container
PILOT
Adjustment Valve
The pilot adjustment valves are located on the manifold
behind the control panel cover.
CAUTION
Turn off the gas supply at the manual shutoff
valve that is next to the broiler before
attempting to loosen any gas connections.
1. Remove the control panel cover as described
under COVERS AND PANELS to access the
pilot valve.
2. Disconnect the gas line from the back of the valve.
3. Unscrew the pilot valve from the manifold.
4. Install the new pilot valve with the adjustment
screw facing the front of the broiler.
NOTE: Make sure that the pipe joint compound or
pipe thread sealant that is being used is resistant
to the corrosive actions of liquefied petroleum gases.
5. Connect the gas line to the back of the valve.
6. Turn the main gas shutoff valve to broiler to the
ON position.
WARNING
ALL GAS JOINTS DISTURBED DURING
SERVICING MUST BE CHECKED FOR LEAKS.
CHECK WITH A SOAP AND WATER SOLUTION
(BUBBLES). DO NOT USE AN OPEN FLAME.
7. Light pilot and adjust pilot valve.
8.
Reinstall control panel cover and control valve knobs.
Figure 5. Pilot Valve
Pilot Assembly and Orifice
The pilot assembly is located adjacent to each burner.
The connection for the pilot assembly is accessed by
removing the venturi cover.
CAUTION
Turn off the gas supply at the manual shutoff
valve that is next to the broiler before
attempting to loosen any gas connections.
1. Remove the venturi cover as described in COVERS
AND PANELS.
2. Disconnect gas line from back of pilot assembly.
3. Unscrew the two screws attaching the pilot
assembly and pilot assembly bracket.
NOTE: Check condition of the pilot orifice and
replace if damaged.